Concordance between the indirect VO2max value estimated through the distance in Yo-Yo intermittent recovery test level 1 and the direct measurement during a treadmill protocol test in elite youth soccer players

Authors

  • Moises Arturo Cabrera Hernandez Area of Medicine and Special Test (MEDES), Faculty of Education and Sport Sciences, Institución Universitaria Escuela Nacional del Deporte., Colombia
  • Luis Javier Tafur Tascon Area of Medicine and Special Test (MEDES), Faculty of Education and Sport Sciences, Institución Universitaria Escuela Nacional del Deporte., Colombia
  • Daniel Dylan Cohen Universidad de Santander (UDES),
  • Sergio Andrés García-Corzo Area of Medicine and Special Test (MEDES), Faculty of Education and Sport Sciences, Institución Universitaria Escuela Nacional del Deporte., Colombia http://orcid.org/0000-0003-0678-7468
  • Alexander Quiñonez Sanchez Faculty of Education and Sport Sciences, Institución Universitaria Escuela Nacional del Deporte. Asociación Deportivo Cali., Colombia
  • Camilo Povea Combariza Universidad Nacional, Faculty of Medicine, Bogotá, Colombia, Colombia
  • Carmen Ximena Tejada Rojas IPS, Institución Universitaria Escuela Nacional del Deporte., Colombia

DOI:

https://doi.org/10.14198/jhse.2018.13.Proc2.24

Keywords:

Intermittent exercise, Adolescent, Soccer players, Oxygen consumption, Yo-Yo intermittent recovery 1 test

Abstract

The main aim of this study was to evaluate the concordance between the indirect V ̇O2max value estimated by the distance achieved in the Yo-Yo intermittent recovery test level 1 (YYIR1) and the direct measurement during a treadmill protocol test (TP) in elite youth soccer players. Methods: Fourteen elite under 20 year’s old soccer players from a first division soccer club were evaluated. Test were performed one week apart. In both tests V ̇O2, was measured with an ambulatory gas exchange measurement. YYIR1 estimated V ̇O2max was calculated using the equation described by Bangsbo et al. (2008) and in TP was calculated using American College of Sport Medicine equation. Results: Lin´s concordance correlation coefficient between direct V ̇O2max in TP and estimated V ̇O2max in YYIR1=0.271 (poor concordance). Conclusions: The poor concordance between direct and indirect V ̇O2max measurements in TP and YYIR1, indicated that in an elite population both test, are not good indirect predictors of V ̇O2max, reached in those tests using current predictive equations. The YYIR1 is well established as a performance-relevant test in elite players, but our data suggests that due to its poor concordance with imprecise estimation of V ̇O2max, which should be measured directly if this variable is of specific interest.

Funding

Area of Medicine and Special Test (MEDES), Faculty of Education and Sport Sciences, Institución Universitaria Escuela Nacional del Deporte, Asociación Deportivo Cali.

Downloads

Download data is not yet available.

References

Ahmaidi, S., Collomp, K., Caillaud, C., & Prefaut, C. (1992). Maximal and functional aerobic capacity as assessed by two graduated field methods in comparison to laboratory exercise testing in moderately trained subjects. INT J SPORTS MED, 13(03), 243-248. https://doi.org/10.1055/s-2007-1021261

Altman, D. G., & Bland, J. M. (1983). Measurement in medicine: the analysis of method comparison studies. The statistician, 307-317. https://doi.org/10.2307/2987937

American College of Sports Medicine. (2013). ACSM's guidelines for exercise testing and prescription. Lippincott Williams & Wilkins.

Aziz, A. R., Tan, F. H., & Teh, K. C. (2005). A pilot study comparing two field tests with the treadmill run test in soccer players. J SPORT SCI MED, 4(2), 105.

Bangsbo, J. (1994). Fitness training in football: a scientific approach. August Krogh Inst., University of Copenhagen.

Bangsbo, J., Iaia, F. M., & Krustrup, P. (2008). The Yo-Yo intermittent recovery test. SPORTS MED, 38(1), 37-51. https://doi.org/10.2165/00007256-200838010-00004

Bangsbo, J., Nørregaard, L., & Thorsoe, F. (1991). Activity profile of competition soccer. CAN J SPORT SCI, 16(2), 110-116.

Bland, J. M. and D. G. Altman. 1986. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet I: 307–310. https://doi.org/10.1016/S0140-6736(86)90837-8

Castagna, C., Impellizzeri, F. M., Chamari, K., Carlomagno, D., & Rampinini, E. (2006). Aerobic fitness and Yo-Yo continuous and intermittent tests performances in soccer players: A correlation study. J STRENGTH COND RES, 20(2), 320-325. https://doi.org/10.1519/R-18065.1

Chamari, K., Moussa-Chamari, I., Boussaidi, L., Hachana, Y., Kaouech, F., & Wisløff, U. (2005). Appropriate interpretation of aerobic capacity: allometric scaling in adult and young soccer players. BRIT J SPORT MED, 39(2), 97-101. https://doi.org/10.1136/bjsm.2003.010215

Cooper, K. H. (1968). A means of assessing maximal oxygen intake: correlation between field and treadmill testing. JAMA, 203(3), 201-204. https://doi.org/10.1001/jama.1968.03140030033008

Deprez, D., Coutts, A. J., Lenoir, M., Fransen, J., Pion, J., Philippaerts, R., & Vaeyens, R. (2014). Reliability and validity of the Yo-Yo intermittent recovery test level 1 in young soccer players. J SPORT SCI, 32(10), 903-910. https://doi.org/10.1080/02640414.2013.876088

Gharbi, Z., Dardouri, W., Haj-Sassi, R., Chamari, K., & Souissi, N. (2015). Aerobic and anaerobic determinants of repeated sprint ability in team sports athletes. BIOL SPORT, 32(3), 207. https://doi.org/10.5604/20831862.1150302

Helgerud, J., Engen, L. C., Wisløff, U., & Hoff, J. (2001). Aerobic endurance training improves soccer performance. MED SCI SPORT EXER, 33(11), 1925-1931. https://doi.org/10.1097/00005768-200111000-00019

Jones, R. M., Cook, C. C., Kilduff, L. P., Milanović, Z., James, N., Sporiš, G., ... & Vučković, G. (2013). Relationship between repeated sprint ability and aerobic capacity in professional soccer players. SCI WORLD J, 2013. https://doi.org/10.1155/2013/952350

Krustrup, P., Mohr, M., Amstrup, T., Rysgaard, T., Johansen, J., Steensberg, A., & Bangsbo, J. (2003). The yo-yo intermittent recovery test: physiological response, reliability, and validity. MED SCI SPORT EXER, 35(4), 697-705. https://doi.org/10.1249/01.MSS.0000058441.94520.32

Krustrup, P., Mohr, M., Ellingsgaard, H. E. L. G. A., & Bangsbo, J. (2005). Physical demands during an elite female soccer game: importance of training status. MED SCI SPORT EXER, 37(7), 1242. https://doi.org/10.1249/01.mss.0000170062.73981.94

Leger, L. A., & Lambert, J. (1982). A maximal multistage 20-m shuttle run test to predict $ $dot V $ $ O2 max. EUR J APPL PHYSIOL O, 49(1), 1-12. https://doi.org/10.1007/BF00428958

Lemmink, K. A. P. M., Verheijen, R., & Visscher, C. (2004). The discriminative power of the Interval Shuttle Run Test and the Maximal Multistage Shuttle Run Test for playing level of soccer. J SPORT MED PHYS FIT, 44(3), 233.

Lin, L. I. (1989). A concordance correlation coefficient to evaluate reproducibility. Biometrics 45: 255–268. https://doi.org/10.2307/2532051

Lin, L. I. (2000). A note on the concordance correlation coefficient. Biometrics 56: 324–325.

Martínez-Lagunas, V., & Hartmann, U. (2014). Validity of the Yo-Yo Intermittent Recovery Test Level 1 for direct measurement or indirect estimation of maximal oxygen uptake in female soccer players. INT J SPORT PHYSIOL, 9(5). https://doi.org/10.1123/ijspp.2013-0313

Mauger, A. R., & Sculthorpe, N. (2012). A new VO2max protocol allowing self-pacing in maximal incremental exercise. BR J SPORTS MED, 46(1), 59-63. https://doi.org/10.1136/bjsports-2011-090006

Metaxas, T. I., Koutlianos, N. A., Kouidi, E. J., & Deligiannis, A. P. (2005). Comparative study of field and laboratory tests for the evaluation of aerobic capacity in soccer players. J STRENGTH COND RES, 19(1), 79-84.

Mohr, M., Krustrup, P., & Bangsbo, J. (2003). Match performance of high-standard soccer players with special reference to development of fatigue. J SPORT SCI, 21(7), 519-528. https://doi.org/10.1080/0264041031000071182

Rebelo, A., Brito, J., Seabra, A., Oliveira, J., & Krustrup, P. (2014). Physical match performance of youth football players in relation to physical capacity. EUR J SPORT SCI, 14(sup1), S148-S156. https://doi.org/10.1080/17461391.2012.664171

Stølen, T., Chamari, K., Castagna, C., & Wisløff, U. (2005). Physiology of soccer. SPORTS MED, 35(6), 501-536. https://doi.org/10.2165/00007256-200535060-00004

Strøyer, J., Hansen, L., & Klausen, K. (2004). Physiological profile and activity pattern of young soccer players during match play. MED SCI SPORT EXER, 36(1), 168-174. https://doi.org/10.1249/01.MSS.0000106187.05259.96

Wisloeff, U., Helgerud, J., & Hoff, J. (1998). Strength and endurance of elite soccer players. MED SCI SPORT EXER, 30, 462-467. https://doi.org/10.1097/00005768-199803000-00019

Statistics

Statistics RUA

Published

2018-07-18

How to Cite

Cabrera Hernandez, M. A., Tafur Tascon, L. J., Cohen, D. D., García-Corzo, S. A., Quiñonez Sanchez, A., Povea Combariza, C., & Tejada Rojas, C. X. (2018). Concordance between the indirect VO2max value estimated through the distance in Yo-Yo intermittent recovery test level 1 and the direct measurement during a treadmill protocol test in elite youth soccer players. Journal of Human Sport and Exercise, 13(2proc), S401-S412. https://doi.org/10.14198/jhse.2018.13.Proc2.24

Most read articles by the same author(s)